Which Engineering Inputs Are Needed Before Ordering a Unipole Billboard? | QX Outdoor

Views:109
Update time:2026-10-30

Answer: Engineering inputs include site coordinates, applicable code, basic wind criteria and exposure, billboard dimensions and elevations, face configuration, support geometry, steel material requirements, access and lighting loads, foundation and soil data, and construction constraints. Include any local permitting or authority requirements before structural calculations and fabrication.

Unipole billboard steel frame with twin base pipes assembled on the ground before hoisting

Load Inputs

Wind usually governs billboard design, and the resulting moment scales with the square of the wind speed.

  • Design wind speed and code edition for the exact site

  • Terrain category, exposure and altitude factors

  • Panel and frame weight, plus screen weight for LED displays

  • Ice, snow or seismic requirements where the local code imposes them

Geometry and Performance Inputs

Geometry converts wind pressure into the moment the pole must resist.

  • Panel width and height, and the mounting height to the panel bottom

  • Offset distance for cantilever configurations

  • Deflection limit at the panel edge under service wind

  • Access requirement: ladder, catwalk, or none for ground-serviceable panels

Ground and Site Inputs

The foundation is often the longest lead item on site, so it must be settled early.

  • Soil type, bearing capacity and water table, ideally from a geotechnical report

  • Available space around the base for the foundation footprint

  • Anchor bolt layout and the concrete grade to be used locally

  • Transport access for the pole length and lifting equipment on site

Frequently Asked Questions

Who decides the design wind speed?

The local code does. We propose a value from the code for your site and flag it in the calculation so your local engineer can confirm or adjust it.

How much does the display weight matter?

It matters for the arm and connections and for the foundation, and it becomes critical with LED screens that add both weight and wind area.

Can the pole be shipped in sections?

Yes. Tall poles are usually shipped in flanged or slip-joint sections sized to container and road limits, with the splice designed as part of the structure.

Get a Unipole Design Basis

Send your site, panel size and soil information, and we will return a calculation summary, drawings and export price within 48 hours.

Email: qxbillboard@qxgg.com  |  Tel: +86-311-85651263